INTERNAL BONDING STRENGTH- GB/T18102-2007 (6.3.6) and GB/T17657-1999 (4.8)

1. TOOLS
1.1 Panel Universal Testing Machine accurate to 1N
1.2 Clamping apparatus
1.3 Vernier caliper accurate to 0.05 mm

2. SAMPLING
6*50x50 mm

3. ENVIRONMENTAL CONDITIONS
Temperature: 20(+/-2) ℃
Humidity: 65(+/-5) %

4. TESTING PROCEDURE
4.1 Determine the center points on the 4 sample edges and draw a line between the 2 points on opposite sides of the samples’ center

4.2 Measure the samples’ length (l) and width (b)



4.3 With the help of melted glue, stick the samples to the clamps



4.4 Place the samples on the Panel Universal Testing Machine

4.5 Introduce data in the computer programme, perform the test, record the results and fill the report
σ┴= P max /(l×b)

5. ASSESSING TEST RESULTS
Passing requirement: σ┴≥1.0 MPa





 
  